  Determination of heavy metals in soil byatomic absorption spectrometry(AAS)

  Name: XuFei Group: The 3rd group

  Date: Sep. 20th 2012

  Part 1 The introduction

  1.1The purposes

  (1)Learn how to operate the atomic absorption spectrometry;

  (2)Learn how to do the pretreatment of soil samples;

  (3)Get familiar with the application of atomic absorption spectrometry.

  1.2The principles

  Atomic Absorption Spectrometry (AAS) is a technique for measuring quantities of chemical elements present in environmental samples by measuring the absorbed radiation by the chemical element of interest. This is done by reading the spectra produced when thesample is excited by radiation. The atoms absorb ultraviolet or visible light and make transitions to higher energy levels .

  Atomic absorption methods measure the amount of energy in the form of photons of light that are absorbed by the sample. A detector measures the wavelengths of light transmitted by the sample, and compares them to the wavelengths which originally passed through the sample. A signal processor then integrates the changes in wavelength absorbed, which appear in the readout as peaks of energy absorption at discrete wavelengths. The energy required for an electron to leave an atom is known as ionization energy and is specific to each chemical element. When an electron moves from one energy level to another within the atom, a photon is emitted with energy E. Atoms of an element emit a characteristic spectral line. Every atom has its own distinct pattern of wavelengths at which it will absorb energy, due to the unique configuration of electrons in its outer shell. This enables the qualitative analysis of a sample.

  The concentration is calculated based on the Beer-Lambert law. Absorbance is directly proportional to the concentration of the analyte absorbed for the existing set of conditions. The concentration is usually determined from a calibration curve, obtained using standards of known concentration. Calibration Curve Method: Prepare standard solutions of at least three different concentrations, measure the absorbance of these standard solutions, and prepare a calibration curve from the values obtained. Then measure the absorbance of the test solution adjusted in concentration to a measurable range, and determine the concentration of the element from the calibration curve.

  Part 2 The materials and apparatus

  Atomic absorption spectrometry; Cu hollow cathode lamp; AC voltage stabilizer; oil-free gas compressor; acetylene cylinder; oscillator; sample boat; Erlenmeyer flask with stopper (100 ml); beaker; graduate cylinder; pipette.

  Part 3 The procedure

  3.1 operating procedure for AAS

  (1) inspect major components to ensure operating normal.

  (2) Install required hollow cathode lamp. Select “T” before turning to the power and hollow cathode lamp. Then select appropriate la mp current and preheat for 30min.

  (3) Make sure electrical meter to point to zero and then turn on high-voltage power.

  (4) Select appropriate slit width.

  (5) Rotate monochromator and select required wavelength. If the power meter is too high or low, adjust negative high voltage until the meter reads full scale.

  (6) Adjust light point and wavelength so that the meter represents the maximum value.

  (7) Turn on air compressor and acetylene gas and ignite flame. Adjust the flame appropriately and preheat the burner.

  (8) Inject distilled water into the flame and continue to preheat the burner. Inject distilled water into the flame after each sample.

  (9) Select “E”, inject blank solution into the flame and adjust the meter to zero.

  (10) Optimize analysis conditions and measure standard solution and samples.

  (11) After completion of measurement, turn off acetylene gas valve and then air compressor, cut off gas supply a moment later.

  (12) Select “T” before turning off high voltage power, decrease lamp current and then turn off the lamp. At the same time, all buttons should be on original positions.

  (13) Check the equipment before leaving the laboratory.

  3.2 Determination of soil samples

  (1) Preparation of extracting solution (0.05 mol/l EDTA solution)

  18.6 g of EDTA is dissolved with water in a beaker (500 ml). The PH is adjusted to 7.0 using dilute ammonia. The mixture is transferred into a volumetric flask (1000ml), dilute to the mark and mixed well.

  (2) Treatment of soil samples

  2.50 g of air-dried soil (60- 100 mesh) is put into an Erlenmeyer flask with stopper (100 ml). 12.5 ml of EDTA solution is added. The mixture is shaken for 1h and then filtered. The filtrate is preserved for analysis.

  (3) Preparation of Cu standard stock solution

  0.10 g of Cu is dissolved in 15 ml of (1:1) nitric acid solution. The mixture is transferred into a volumetric flask (1000 ml) and diluted to the mark with re-distilled water. The concentration of the stock standard solution is 100g/ml. (The concentration should be calculated according to the mass of Cu).The working Cu standard solution (10μg/ml) is obtained by diluting 10 ml of Cu standard stock solution to 100 ml with

  re-distilled water.

  (4) Plotting of the standard curve

  0 ml, 1 ml, 2 ml, 3 ml, 4 ml and 5 ml of Cu standard solution (10μg/ml) are added respectively to 6 volumetric flask (10 ml) with 1 ml of 5 mol/l hydrochloric acid. The mixture is diluted with re-distilled water and mixed well to give 0μg/ml, 1.00μg/ml,2.00μg/ml, 3.00μg/ml, 4.00μg/ml, 5.00μg/ml of Cu, respectively. The absorbance is measured at wavelengths of 3247 ?. The standard curve is constructed by plotting absorbance vs. concentration.

  (5) Determination of samples

  The sample solution is analyzed using the same procedure and conditions as for the standard curve. The concentration of Cu is obtained from the standard curve based on the absorbance.

  Part 4 The results

  4.1 The raw data

  4.2 AAS standard curve

  4.3 Calculation

  The absorbance of sample is 0.0511.

  According to the formula above :y=0.0446x+0.0024,R2=0.9997

  The concentration of Cu in the sample is:1.091mg/L.

  Part 5 Discussion

  In this experiment, we use the AAS to determine Cu in soil. I learn how to operate the AAS and the limitation. In the experimental process, standard solution was prepared in strict accordance with the experimental requirements and I learn how to deal with the data. Finally we get the standard curve, then, the sample concentration is calculated according to the absorbance of the sample.

  In the experiment we have nine members in our group, so we can do our best in every work we need to do. For my work, I am responsible for the preparation of solution and titration. What’s more, I learn how to use and operate the AAS on the computer later.

  Ultimately, we get the linear formula is y = 0.0446x + 0.0024 and R2=0.9997. From According to the formula and the absorbance of Cu in the sample is 0.0511, we draw the concentration of Cu in the sample is 1.091μg/ml. We have known that the concentration of test sample measured by instrument is 1.091mg/L.

  We can say our result of experiment is so very accurate from the standard curve of Cu and the value of R(R2=0.09997). The accurate data is due to the efforts of we everyone. Thanks for every members of our group.

  I have some suggestions for our experiments. Firstly when we’ll do an experiment, we must prepare our pre-lab by ourselves and translate it into Chinese .Only do like this, we can understand the experiment well. Secondly we should prefer to solute the problems in the experiment rather than ask for TA. Finally, everyone should understand his own task in the experiment.

【關于英語實驗報告】相關文章:

實驗報告范文01-20

倉儲實踐實驗報告01-13

實驗報告范文(15篇)01-20

實驗報告范文15篇01-20

實驗報告范文(集錦15篇)01-20

《血染的實驗報告》讀后感01-20

民間文學課題實驗報告01-20

《血染的實驗報告》讀后感3篇01-20

關于留學英語推薦信閱讀10-20

有關于英語推薦信閱讀10-14

主站蜘蛛池模板: 欧美怡红院视频一区二区三区| 丝袜国产一区| 成人精品视频一区二区在线| 国产成人综合日韩精品无码首页| 婷婷色丁香综合激情| 国产在线观看成人91| 精品无码一区二区在线观看| 日本少妇又色又爽又高潮| 亚洲成av人无码综合在线观看| 欧美一级黄片一区2区| 黄色一及毛片| 日韩亚洲高清一区二区| 美女免费黄网站| 青青操视频在线| 国产精品999在线| 免费久久一级欧美特大黄| 老司机精品久久| 亚洲动漫h| 久久不卡国产精品无码| 精品无码日韩国产不卡av| 国产一区自拍视频| 国产精品综合久久久| av一区二区无码在线| 91麻豆精品视频| 亚洲精品成人片在线观看 | 国产激情影院| 国产哺乳奶水91在线播放| 亚洲综合片| 深夜福利视频一区二区| 国产精品永久免费嫩草研究院| 欧美特黄一免在线观看| 亚洲欧美天堂网| 国产人免费人成免费视频| 91亚瑟视频| 97在线公开视频| 国产XXXX做受性欧美88| 夜夜操国产| 国产青榴视频| 亚洲日韩精品欧美中文字幕| 一个色综合久久| 国产内射一区亚洲| 亚洲天堂网在线播放| 精品福利国产| 久久无码高潮喷水| 中文字幕第4页| 五月天天天色| 天天摸夜夜操| 一级全黄毛片| 久久黄色视频影| a级毛片免费播放| 久久久精品久久久久三级| 99re视频在线| 天天综合色网| 国产欧美日韩18| 在线观看国产精美视频| 91精品免费久久久| 青青草原国产免费av观看| 日韩中文无码av超清| 色婷婷久久| 国产网友愉拍精品视频| 蜜桃视频一区二区| 成人福利一区二区视频在线| 少妇高潮惨叫久久久久久| 高清久久精品亚洲日韩Av| 一级一级特黄女人精品毛片| 东京热高清无码精品| 国产精品lululu在线观看| 国产综合无码一区二区色蜜蜜| 亚洲综合18p| 国产在线专区| 午夜a级毛片| 青草视频久久| 亚洲女同欧美在线| 免费高清a毛片| 久久精品波多野结衣| 成人免费午间影院在线观看| 精品一区二区无码av| a亚洲天堂| 精品一区二区三区无码视频无码| 中文字幕在线日韩91| 四虎永久在线精品影院| 亚洲国产精品不卡在线|